In short
The six facts an engineer needs to select an induced draft blower: gas, temperature, airflow, pressure, duty and site. Plus normal vs actual flow.
By Karan Dargode, Manager, Operations & EHS, AS Engineers. Updated on November 26, 2026.
Replacing an underperforming or rusted induced draft blower without handing the manufacturer shaft centerline height, discharge orientation, and measured system static pressure slows procurement down by weeks of avoidable drawing revisions. On plant retrofits, dropping a new blower onto existing concrete anchor bolts and baghouse duct transitions saves days of expensive shutdown crane work when those dimensions sit in the RFQ from Day 1. This field-ready checklist shows plant buyers exactly what to send for an induced draft blower quote alongside our exhaust blower selection specs.
In short: Essential data for fast, exact ID blower quotations
- Measure running plant duty if nameplates are lost: Record equal-area Pitot velocity pressure, inlet/outlet duct static taps, temperature, and motor amps using our Pitot-tube measurement procedure.
- State standard rotation & discharge orientation per AMCA 99: Confirm CW vs CCW viewing from the drive side plus discharge angle (e.g., Bottom Horizontal, Top Vertical, Up-Blast 45) using AS Engineers blower rotation guides.
- Specify drive Arrangement (Arr. 1, 4, 8, or 9) and motor voltage/VFD needs: Belt-driven Arr. 9 simplifies minor post-install speed tweaks; Arr. 8 direct coupling cuts belt maintenance above 45 kW.
- Share existing concrete pier & flange dimensions for retrofits: Anchor bolt center-to-center pitches allow exact drop-in baseframe fabrication with zero civil breaking.
- Benchmark complete RFQ sheets cleanly: Cross-check standard datasheets on centrifugal blower RFQ datasheets and high-static pressure guides.
Plant teams served: Plant maintenance engineers, retrofit spares buyers, utility supervisors, and EPC procurement specialists.
Complete 10-Point ID Blower RFQ & Retrofit Datasheet
For: Maintenance manager, retrofit procurement
| # | RFQ Data Field | Required Units / Details | Why Missing This Slows Delivery |
|---|---|---|---|
| 1 | Design & Upset Gas Flow | Actual Am3/h (or ACFM) at operating temp | Fixes wheel width, eye velocity, and scroll geometry |
| 2 | Total Developed Static Pressure | mmWC or Pa (Outlet SP minus Inlet Suction) | Controls impeller OD, RPM, and motor horsepower directly |
| 3 | Inlet Gas Temp & Elevation | Normal C, Peak C, and plant metres ASL | Adjusts air density ratio (hot running kW vs cold-start overload) |
| 4 | Gas Composition & Dust Load | mg/Nm3 dust, moisture/dewpoint, acid/halide ppm | Selects backward vs radial wheel & Corten/SS/FRP/wear-plate MOC |
| 5 | Drive Arrangement (AMCA 99) | Arr. 1, Arr. 4, Arr. 8, or Arr. 9 (belt piggyback) | Determines bearing pedestals, coupling guards, and heat protection |
| 6 | Rotation & Discharge Angle | CW / CCW from drive side + THD/BHD/UBD deg | Prevents backward-wired scroll orientation blocking site ducts |
| 7 | Existing Flange & Centerline Height | Inlet ID, Outlet WxH, Base-to-shaft height (mm) | Lets new casing bolt cleanly onto existing baghouse/stack transitions |
| 8 | Concrete Pier Bolt Pattern (Retrofit) | Length x Width pitch + slot sizes + motor side | Drop-in skid aligns onto existing anchors without civil breaking |
| 9 | Available Motor & VFD Control | IE3/IE4 spec, flameproof Zone, 415V/690V, VFD range | Prevents starter/cable under-sizing during cold purge amps |
| 10 | QA & Scope Extras | ISO 1940 G2.5/G6.3, PMI, inlet damper, bellows | Aligns vendor prices apples-to-apples without hidden add-ons |
Worked Retrofit Example: Ordering a Drop-In Any-OEM Replacement Without Civil Breaking
For: Maintenance head, shutdown planner
Suppose a chemical plant needs to replace a rusted 12-year-old third-party baghouse ID blower whose original manufacturer went out of business, working inside a strict 48-hour weekend shutdown window:
- The maintenance supervisor measures existing concrete foundation bolt centers (
1,850 mm x 1,100 mm), bottom-to-shaft centerline height (920 mm), round inlet flange (600 mm OD), and rectangular outlet flange (520 x 440 mm, Top Horizontal Discharge CW viewed from motor end). - A quick Pitot traverse shows the baghouse actually pulls 21,500 Am3/h at 140 C against 340 mmWC static pressure (existing unit struggled because worn inlet cone overlap leaked 18% air internally).
- Sending those exact 10 fields plus 4 smartphone photos allows AS Engineers to fabricate a dynamically balanced Corten-A / SS 316L replacement unit matching the exact foundation anchor pitch and flange positions, sliding onto existing bolts in under four hours with zero civil chipping!
Five photos to attach alongside your RFQ email for 24-hour engineering turnaround
For: Site technician, buyer
- Wide-angle front view showing full blower, motor pedestal, and inlet/outlet ducting (identifies arrangement and rotation instantly).
- Side view showing inlet duct elbow spacing and expansion joints (catches System Effect loss early).
- Close-up of legible motor nameplate and any surviving blower serial tag.
- Close-up of concrete foundation anchor pads relative to housing feet.
- Inspection hatch photo (when stopped safely) showing dust build-up pattern or blade leading-edge wear.
Frequently Asked Questions on Induced Draft Blower Quotes
How long does AS Engineers take to quote an induced draft blower?
When all 10 technical inputs (or field Pitot measurements plus photos for a retrofit) accompany the inquiry, our Vatva engineering team prepares aerodynamic curve selection, motor power sizing, and commercial pricing promptly with clear GA specifications.
Can I reuse my existing electric motor and foundation on an ID blower replacement?
Often yes, provided motor winding insulation tests healthy, kW covers corrected cold/hot duty margin, and exact shaft height plus baseframe hole pitches are supplied before we draft the General Arrangement drawing.
What extra accessories should I ask to be itemized separately on my quote?
Request itemized options for inlet radial vane dampers (or VFD readiness), non-metallic inlet/outlet flexible expansion bellows, spring anti-vibration mountings, casing drain/inspection doors, and spare spherical roller bearings or shaft seals.
Does AS Engineers provide on-site dimensional reverse-engineering if the old blower has no drawings?
Yes. Founded in 1997 in Vatva, Ahmedabad (ISO 9001:2015), AS Engineers conducts site surveys covering airflow, static pressure, vibration, and dimensional bolt/flange measurement for exact any-OEM replacement builds.
Your next step by department
- Maintenance & Projects: Snap the 5 photos above and capture anchor-bolt and flange dimensions during your next inspection walkdown.
- Procurement: Paste the 10-point RFQ table cleanly into vendor bid packages so every supplier sizes to identical density and static pressure numbers.
- Take action: Upload your site datasheet or schedule a retrofit survey via our induced draft blower quote desk.
About the author: Karan Dargode leads Operations and EHS at AS Engineers in Vatva, Ahmedabad, where he has managed shop-floor manufacturing, assembly, and on-site equipment commissioning since 2019. He holds a B.E. in Mechanical Engineering from GTU and a PGDBA in Operations from Symbiosis. Connect with Karan on LinkedIn.
Sources
- Air Movement and Control Association (AMCA): Standard 99 Fan Arrangements, Rotation & Discharge Designations (amca.org).
- AMCA Publication 203: Field Performance Measurement of Fan Systems (amca.org).
- International Organization for Standardization: ISO 21940-11 Balance Quality Requirements (iso.org).
- Bureau of Indian Standards (BIS): IS 4894 Centrifugal Fans Specification (bis.gov.in).
- B.E. Mechanical · GTU (2018)
- PGDBA, Operations · Symbiosis
- With AS Engineers since 2019
- Writes on fans, blowers & plant reliability
Karan Dargode leads operations and environmental health & safety at AS Engineers, the Ahmedabad manufacturer of centrifugal fans and blowers, bag filters, pneumatic conveying systems and paddle dryers. He writes practical guides on induced draft blower selection, material handling and plant reliability.