ID Blower Material by Temperature, Acid Dew Point & Erosive Dust (0 to 350 C)

In short

Which metal for which gas temperature: mild steel, SS 304, SS 321 and SS 310 from ambient to 650 °C, plus bearing cooling and what changes when gas gets hot.

By Karan Dargode, Manager, Operations & EHS, AS Engineers. Updated on November 26, 2026.

Selecting an induced draft exhaust blower material solely from maximum gas temperature misses the two fastest impeller killers in chemical and APC plants: acidic dew-point condensation below 140 C and abrasive particulate erosion downstream of cyclones. A wet caustic or HCl fume stream at just 55 C shreds mild steel housings within four months, whereas dry biomass ash at 220 C slices unlined carbon steel blades paper-thin in one operating season. This chemical and erosion MOC matrix helps engineers specify induced draft blower materials cleanly across process exhaust & retrofit blowers.

In short: Exhaust MOC selection beyond dry temperature

  • Acid dew point kills warm carbon steel fastest: Anytime sulfur-bearing flue gas or moist scrubbers cool near sulfuric/hydrochloric dew point (~95 to 145 C), condensation pits plain IS 2062 steel rapidly.
  • Wet corrosive fumes (up to 90 C): Specify heavy industrial FRP casings (derated chemical vinyl-ester resin), ebonite rubber-lined MS, or SS 316L / Alloy 20 wheels with drains and shaft seals.
  • Abrasive dry flue dust (150 to 350 C): Deploy Corten-A weathering casings with bolted Hardox / manganese or tungsten-carbide hardfaced radial wear liners.
  • Hot-zone metallurgical kilns (350 to 650+ C) stay specialized: Above ~350 to 400 C dry continuous kiln duty, consult alloy creep standards on heat-resistant steels for furnace fans.
  • Protect against dirty wet-scrubber surprises: Cross-check wet scrubber system pressure sizing cleanly on wet scrubber sizing guides and industrial exhauster wheels.

Plant teams served: Chemical EHS managers, APC scrubber/baghouse maintenance engineers, boiler utility leads, and procurement QA buyers.

Which MOC survives wet scrubbers, acid mist, or abrasive exhaust best up to 350 C?

For: Process specifier, materials engineer, maintenance

Gas Condition & TemperatureRecommended Wetted Casing / Wheel MOCKey Chemical / Mechanical LimitCritical Inspection Check
Clean / mild dry exhaust (0 to 250 C)IS 2062 / ASTM A36 mild steel with heat-resistant epoxy or aluminium paintFails fast if wet HCl, Cl2, or HF mist or below-dewpoint sulfur condensesInclude bottom casing drain plug + inspect blade roots yearly
Wet acid / HCl / SO2 scrubber tail gas (20 to 85 C)FRP (bisphenol / vinyl-ester) casing + FRP-encapsulated or Alloy/SS 316L wheelNever exceed ~85 to 95 C resin heat-distortion ceiling; watch fluoride attack on glass fiberVerify spark/pinhole test on resin lining + PTFE lip seal at shaft exit
High-chloride / neutral wet brine vapor (30 to 120 C)Duplex 2205 (UNS S32205) or Ebonite rubber-lined MS casing (under ~75 C)SS 304 and SS 316L risk crevice/pitting corrosion in concentrated warm chloridesRequire post-weld pickling/passivation + PMI verification certificate
Sulfur flue gas near acid dew point (110 to 250 C)Corten-A (IRSM-41 / ASTM A588) or SS 316LCopper-chromium-nickel weathering alloy slows sulfuric condensate pitting vs A36Maintain boiler/baghouse outlet temperature safely above acid dew point
Erosive fly ash, cement dust, or silica (120 to 350 C)ASTM A516 Gr.70 / Corten casing + bolted Hardox / Chromium-Carbide wear linersFlat radial or radial-tip paddles resist sandblasting; clean backward curved shrouds cut rapidlyWeight-balance replaceable liner sets to ISO 1940 G6.3 after replacement

Worked Maintenance Case: Why an 80 C Wet Scrubber Fan Eats Uncoated Mild Steel Fast

For: ETP/APC maintenance manager, finance

Many plants assume an 80 C gas stream needs only coated mild steel because ambient A36 steel keeps full strength up to 250 C. Yet look at what actually happens downstream of a packed-bed alkali or acid scrubber when mist eliminators pass even minor droplets:

  • High tip speed (50 to 85 m/s) flings entrained 50-micron acid droplets violently against blade leading edges and the bottom casing scroll belly.
  • That continuous droplet impingement strips standard industrial paint off in under 60 days, exposing raw mild steel to oxygen-rich acidic moisture at 80 C where corrosion rates multiply several millimetres per year.
  • Once corrosion eats 3 mm unevenly off one impeller blade, centrifugal unbalance spikes ISO 10816 vibration past 11 mm/s RMS, destroying plummer block spherical roller bearings!
  • Fix: Switching wet corrosive exhaust fans cleanly to vinyl-ester FRP or Duplex / SS 316L wetted parts alongside a bottom casing drain loop stops recurring 6-month impeller replacements permanently. Check airflow testing steps before ordering replacements via Pitot-tube exhaust measurement and ID fan maintenance checklists.

Five exhaust blower design features that double MOC life in the field

For: Reliability engineering, procurement

  1. Bolted scroll cleanout door + bottom flanged drain plug: Wet condensates and slurry buildup sit in the bottom scroll dead-zone; letting maintenance flush deposits out during weekly stops prevents acidic crevice corrosion.
  2. Air-purged PTFE / viton shaft stuffing box: Keeps corrosive acid fumes inside the scroll instead of creeping down the shaft to rust expensive steel bearings.
  3. Bolted split casing (above ~800 mm wheel OD): Allows crane lifting of just the heavy wear-lined impeller shaft assembly during tight plant shutdowns without cutting heavy inlet/outlet ductwork.
  4. Replaceable scroll liner plates: Line only the high-wear outer scroll wrap and radial blade leading faces with Hardox / chromium-carbide overlays rather than discarding entire housings.
  5. Full PMI + spark/DP inspection before dispatch: Verify every welded plate matches order grade per GA approval and PMI checklists.

Frequently Asked Questions on ID Blower Material Selection

Can I use SS 304 for wet sulfuric or hydrochloric acid fumes at 60 C?

No. Standard SS 304 pits rapidly in hydrochloric chlorides and warm acidic mist. Specify vinyl-ester FRP, rubber-lined steel, Duplex 2205, or high-nickel alloy construction matched directly to your scrubber pH and halide ppm.

What temperature limits rubber-lined and FRP exhaust blowers?

Most industrial rubber linings and chemical-grade vinyl-ester FRP casings operate reliably up to roughly 75 C to 90 C continuous gas temperature. Any dry upset spike above ~100 C requires stainless steel or metallic liners with quench emergency spray interlocks.

Why is Corten-A steel popular on biomass and coal boiler ID fans?

Corten-A atmospheric weathering steel forms a tighter protective oxide patina than mild steel during warm-up/cool-down acid condensation cycles, significantly outlasting IS 2062 steel around 130 C to 250 C.

Can AS Engineers upgrade a corroded mild steel ID blower to SS 316L or wear-lined construction using the existing foundation?

Yes. AS Engineers fabricates replacement corrosion-resistant and hardfaced impellers, shafts, and split housings tailored to match existing baseplate anchor bolts and duct flange centerlines.

Your next step by department

  • Process & EHS: Test mist-eliminator outlet pH, chloride/fluoride ppm, and minimum/maximum gas temperature (do not report normal temp alone!).
  • Maintenance & Procurement: Request bolted split housings, casing drain ports, and replaceable scroll liners in your retrofit RFQ.
  • Take action: Share your gas chemistry and existing housing dimensions through our ID blower engineering desk for an MOC recommendation.

About the author: Karan Dargode leads Operations and EHS at AS Engineers in Vatva, Ahmedabad, where he has managed shop-floor manufacturing, assembly, and on-site equipment commissioning since 2019. He holds a B.E. in Mechanical Engineering from GTU and a PGDBA in Operations from Symbiosis. Connect with Karan on LinkedIn.

Sources

  • ASTM International: ASTM A240M Stainless Steel & ASTM A588 Corten Structural Standards (astm.org).
  • Central Pollution Control Board (CPCB): Acid Mist & Particulate Scrubber Tail-Gas Standards (cpcb.nic.in).
  • International Organization for Standardization: ISO 21940-11 Rotor Balancing & ISO 10816 Vibration Criteria (iso.org).
  • Nickel Institute: Corrosion Guidelines for Stainless Steels & Duplex Alloys in Wet Acid/Chloride Service (nickelinstitute.org).
Written by Karan Dargode Manager – Operations & EHS, AS Engineers
  • B.E. Mechanical · GTU (2018)
  • PGDBA, Operations · Symbiosis
  • With AS Engineers since 2019
  • Writes on fans, blowers & plant reliability

Karan Dargode leads operations and environmental health & safety at AS Engineers, the Ahmedabad manufacturer of centrifugal fans and blowers, bag filters, pneumatic conveying systems and paddle dryers. He writes practical guides on induced draft blower selection, material handling and plant reliability.

Tell us your gas and temperature. We will select your fan.

Share the gas, temperature, airflow and pressure. Get a fan recommendation and a quote within one working day.

Request your free quote

Step 1 of 2 · takes 30 seconds
What do you need?

Airflow, if you know it (m³/hr)

No spam · reply within one working day

Where should we send your proposal?

Prefer to talk? +91 99090 33851 · WhatsApp

Ready when you are

Induced draft blowers built for reliable plant exhaust.

Tell us your gas, temperature and airflow. We reply with a fan recommendation within one working day.

[ase_paddle_divider]
Chat with us
Secure form

Get your blower quote

Step 1 of 2 · takes 30 seconds
What do you need?

Airflow, if you know it (m³/hr)

No spam · reply within one working day

Where should we send your proposal?

Prefer to talk? +91 99090 33851 · WhatsApp

SSL-encrypted. Your details go only to our engineers – never shared or sold.