Backward curved ID blowers
Efficient centrifugal blowers with a non-overloading power curve. The usual choice for clean or lightly dusty flue gas, and they can also serve as forced draft blowers.
Best for Clean to lightly dusty flue gas
Get a quoteAhmedabad
AS Engineers builds induced draft blowers at GIDC Vatva, Ahmedabad, since 1997. Site visit, custom engineering and after-sales support for plants across India.
Ahmedabad
AS Engineers designs and builds industrial fans and blowers at its works in GIDC Vatva, Ahmedabad, and has done so since 1997. We work with plants around Ahmedabad and across India.
A manufacturer next door means a faster technical discussion, a site visit before the quote, and one team for the fan, the drive and the after-sales support.
Why local helps
Your plant team can meet our engineers, see the furnace and agree the duty before anything is fabricated.
Impeller, casing, shaft and drive come from one works, so the specifications match.
Spare parts, bearing and seal replacement, and help when your duty changes.
What we supply
AS Engineers designs and builds induced draft blowers for furnaces, boilers and kilns, in backward curved, radial blade and high temperature plug designs. Pick the one you need, or tell us your duty and we will recommend it.
Efficient centrifugal blowers with a non-overloading power curve. The usual choice for clean or lightly dusty flue gas, and they can also serve as forced draft blowers.
Best for Clean to lightly dusty flue gas
Get a quoteA sturdier impeller shape for dusty, dirty or sticky flue gas and for high static pressure. Open or closed configurations.
Best for Dusty, dirty or sticky gas
Get a quoteSingle or double inlet fans for hot air and gas up to 650 C, with the material, bearing and cooling arrangement chosen for the temperature.
Best for Furnaces, ovens, kilns and hot gas recirculation
Get a quoteHigh pressure radial blade blowers for duties where the furnace, heat recovery and duct add a lot of resistance.
Best for High static pressure
Get a quoteIndustrial exhauster blowers for furnace exhaust, fume and process air handling.
Best for Furnace exhaust and process air
Get a quoteWhen the duty point is not a standard one, we engineer the impeller, casing and drive to your specification.
Best for Retrofit or a one-off duty
Get a quoteIndustries
Plants that burn fuel or handle hot air and gas, and need the draught to stay steady.
Kiln induced draft fans and raw mill fans
Forced draft and induced draft fans, flue gas handling
Combustion air supply and furnace exhaust
Furnace air supply and hot gas handling
Kiln and furnace air and gas
Process heaters, dryers and exhaust
Heat treatment furnace air supply
Dryers, ovens and heat recovery
Visit or call
Plot No-514, Phase-II, Near Vatva Railway Station, GIDC, Vatva, Ahmedabad, Gujarat 382445, India.
Plot No-514, Phase-II, Near Vatva Railway Station, GIDC, Vatva, Ahmedabad, Gujarat 382445, India
Plot No-CIB-160, Phase-II, GIDC, Vatva, Ahmedabad, Gujarat 382445, India
FAQ
An induced draft (ID) blower, also called an ID fan, is an industrial centrifugal fan that sits after a furnace, boiler or kiln. It draws the hot flue gas through the heat recovery section and duct and sends it to the stack. By doing this it holds the furnace at a slight negative pressure, which keeps flame and gas inside the furnace.
An induced draft (ID) blower, also called an ID fan, is an industrial centrifugal fan that sits after a furnace, boiler or kiln. It draws the hot flue gas through the heat recovery section and duct and sends it to the stack. By doing this it holds the furnace at a slight negative pressure, which keeps flame and gas inside the furnace.
A forced draft (FD) fan sits before the furnace and pushes combustion air in. An induced draft (ID) fan sits after the furnace and draws the flue gas out. The FD fan handles clean air near ambient temperature. The ID fan handles hot, often dusty flue gas, so its material, bearings and cooling are chosen for that.
A forced draft (FD) fan sits before the furnace and pushes combustion air in. An induced draft (ID) fan sits after the furnace and draws the flue gas out. The FD fan handles clean air near ambient temperature. The ID fan handles hot, often dusty flue gas, so its material, bearings and cooling are chosen for that.
Backward curved and radial blade centrifugal blowers, high temperature plug blowers, high pressure radial blade blowers, industrial exhausters and blowers made to order. They are built at our works in GIDC Vatva, Ahmedabad.
Backward curved and radial blade centrifugal blowers, high temperature plug blowers, high pressure radial blade blowers, industrial exhausters and blowers made to order. They are built at our works in GIDC Vatva, Ahmedabad.
Vatva GIDC works & engineering
From our Vatva Phase II works in Ahmedabad, AS Engineers handles heavy plate fabrication, heat-resistant welding, dynamic rotor balancing, and on-site fan retrofits across Gujarat and India.
Review our shop inspection workflow and quality controls on the about AS Engineers page, explore commissioning, vibration diagnostics, and replacement rotors under ID blower services and spares, or prepare drop-in measurements with our retrofit RFQ and field audit checklist.
Learn more about our parent engineering group on about AS Engineers and review aerodynamic selection curves in the centrifugal blower selection and sizing guide.
Standards Referenced: ISO 9001:2015 Quality Management & ISO 21940-11 Rotor Balancing; AMCA Standard 210 & 99 Aerodynamic Testing; Central Pollution Control Board (CPCB) Emission & Draft Norms.
Share the gas, temperature, airflow and pressure. Get a fan recommendation and a quote within one working day.