Backward curved ID blowers
Efficient centrifugal blowers with a non-overloading power curve. The usual choice for clean or lightly dusty flue gas, and they can also serve as forced draft blowers.
Best for Clean to lightly dusty flue gas
Get a quoteProduct guide
Induced draft blowers from AS Engineers: they draw hot flue gas out of a furnace or boiler. Airflow 100 to 2,50,000 m3/hr, static pressure 25 to 2,100 mmWC, gas to 650 °C.
What it is
An induced draft (ID) blower, also called an ID fan, is an industrial centrifugal fan that sits after a furnace, boiler or kiln. It pulls the hot flue gas through the heat recovery section and the duct and sends it to the stack. This holds the furnace at a slight negative pressure and keeps flame and gas inside.
AS Engineers designs and builds induced draft blowers in Ahmedabad, as backward curved and radial blade industrial exhauster blowers and as high temperature plug blowers, for gas from ambient temperature up to 650 °C.
The full AS Engineers range of blowers and fans is on theasengineers.com.
What we supply
AS Engineers designs and builds induced draft blowers for furnaces, boilers and kilns, in backward curved, radial blade and high temperature plug designs. Pick the one you need, or tell us your duty and we will recommend it.
Efficient centrifugal blowers with a non-overloading power curve. The usual choice for clean or lightly dusty flue gas, and they can also serve as forced draft blowers.
Best for Clean to lightly dusty flue gas
Get a quoteA sturdier impeller shape for dusty, dirty or sticky flue gas and for high static pressure. Open or closed configurations.
Best for Dusty, dirty or sticky gas
Get a quoteSingle or double inlet fans for hot air and gas up to 650 C, with the material, bearing and cooling arrangement chosen for the temperature.
Best for Furnaces, ovens, kilns and hot gas recirculation
Get a quoteHigh pressure radial blade blowers for duties where the furnace, heat recovery and duct add a lot of resistance.
Best for High static pressure
Get a quoteIndustrial exhauster blowers for furnace exhaust, fume and process air handling.
Best for Furnace exhaust and process air
Get a quoteWhen the duty point is not a standard one, we engineer the impeller, casing and drive to your specification.
Best for Retrofit or a one-off duty
Get a quoteHow it works
The ID blower takes the gas away. The FD blower feeds the air in.
The forced draft fan pushes combustion air to the burners or grate. The air volume must match the fuel being burnt.
Fuel burns in the furnace or boiler and makes hot flue gas. The furnace works best at a slight negative pressure.
The induced draft fan sits after the furnace and draws the flue gas through the heat recovery and duct. It sets the furnace draught.
The gas leaves through the stack. A bag filter or other dust control sits before the stack where the process needs it.
ID fan vs FD fan
A furnace normally has both. They do different jobs and are built differently.
| Forced draft (FD) fan | Induced draft (ID) fan | |
|---|---|---|
| Position | Before the furnace | After the furnace |
| Handles | Clean combustion air | Hot, often dusty flue gas |
| Pressure effect | Raises pressure in the furnace | Lowers pressure in the furnace (draught) |
| Main concern | Air volume to match the fuel | Temperature, dust and corrosion |
| Typical impeller | Backward curved | Backward curved or radial blade, by dust load |
| Material | Usually mild steel | Chosen from the gas temperature and composition |
Range
These are the stated ranges of the AS Engineers centrifugal fan and blower range. Your own duty point decides the actual fan.
| Parameter | Range |
|---|---|
| Airflow | 100 to 2,50,000 m³/hr (design up to 3,50,000 m³/hr) |
| Static pressure | 25 to 2,100 mmWC |
| Motor power | 0.5 to 500 HP |
| Impeller diameter | 250 to 2,200 mm |
| Fan speed | 300 to 4,500 RPM |
| Operating temperature | Ambient up to 650 °C |
| Performance testing | IS 4894 (BIS) |
| Dynamic balancing | ISO 1940-1, Grade G6.3 / G2.5 |
| Quality system | ISO 9001:2015 certified |
Fan parts
Each part has one job. A fan lasts when all of them are chosen for the same gas and the same temperature.
The wheel that moves the gas. Backward curved blades give a non-overloading power curve and good efficiency. Radial blades suit dirty or sticky gas.
The scroll casing guides the gas to the outlet. Single inlet (SWSI) or double inlet (DWDI) construction is chosen from the airflow.
Fixed and floating bearings take the thermal growth. Stuffing box or mechanical seal keep hot gas inside the casing.
Shaft cooler, cooling disc and an insulated pedestal keep the bearing temperature down when the gas is hot.
Mild steel, carbon steel, stainless steel grades or duplex, chosen from the gas temperature and how corrosive or abrasive it is.
Belt-driven or direct-coupled, in the standard drive arrangements. A separated pedestal design is used at high temperature.
Bellows take up duct expansion so hot ducting does not load the fan. Inlet vane or damper control the airflow.
Starter or variable frequency drive, and vibration and temperature sensors for safe, stable running.
Temperature and material
AS Engineers builds fans for gas from ambient up to 650 °C. The hotter the gas, the more the material, bearing arrangement and cooling matter.
| Gas temperature | Typical material | Notes |
|---|---|---|
| Up to 150 °C | Mild steel | Standard construction |
| 150 to 250 °C | Mild steel or SS 304 | Choice depends on the gas and how corrosive it is |
| 250 to 350 °C | Mild steel, SS 304 or SS 321 | Separated pedestal design is used above about 300 °C |
| 350 to 500 °C | SS 321 or SS 310 | Shaft cooler and insulated pedestal |
| 500 to 650 °C | SS 310 or a high temperature alloy | Every duty is reviewed individually |
These are typical choices. The final choice depends on the gas composition, how corrosive or abrasive it is, and whether the temperature is steady or cycles.
Hot gas volume calculator
Hot gas takes up more room. Enter the flow at normal conditions and the gas temperature, and see the actual volume the fan has to move and the material usually used at that temperature.
*Indicative only. Actual volume = normal volume × (273 + gas temperature) ÷ 273, at the same pressure. Real selection also depends on gas density and composition, altitude, duct resistance and the fan curve, so we size every fan from your duty data.
Before we quote
Do not worry if you do not have all of them. Send what you know, and our engineers will ask for the rest.
Hot air, flue gas or process gas, with its composition if it is corrosive, wet or dusty.
Normal and peak gas temperature at the fan inlet.
Volume in m3/hr or Nm3/hr, and whether it is at actual or normal conditions.
Static pressure the fan must develop, or the duct and furnace resistance.
Induced draft, forced draft or recirculation, number of fans, standby needs.
Power supply, space limits, a layout sketch, fuel and any CPCB or safety requirements.
FAQ
Our centrifugal fan range covers operating temperatures from ambient up to 650 °C. The material and construction change with temperature: mild steel at lower temperatures, then SS 304, SS 321 and SS 310 as the gas gets hotter. Duties above 500 °C are reviewed one by one.
Our centrifugal fan range covers operating temperatures from ambient up to 650 °C. The material and construction change with temperature: mild steel at lower temperatures, then SS 304, SS 321 and SS 310 as the gas gets hotter. Duties above 500 °C are reviewed one by one.
Airflow from 100 to 2,50,000 m³/hr, with designs up to 3,50,000 m³/hr, and static pressure from 25 to 2,100 mmWC. The motor range is 0.5 to 500 HP and the impeller diameter 250 to 2,200 mm.
Airflow from 100 to 2,50,000 m³/hr, with designs up to 3,50,000 m³/hr, and static pressure from 25 to 2,100 mmWC. The motor range is 0.5 to 500 HP and the impeller diameter 250 to 2,200 mm.
A backward curved impeller gives good efficiency and a power curve that does not overload the motor, so it is the usual choice for clean or lightly dusty gas. A radial blade impeller is a sturdier shape that suits dusty, dirty or sticky gas and high pressure duty.
A backward curved impeller gives good efficiency and a power curve that does not overload the motor, so it is the usual choice for clean or lightly dusty gas. A radial blade impeller is a sturdier shape that suits dusty, dirty or sticky gas and high pressure duty.
A shaft cooler and a cooling disc carry heat away from the shaft, and an insulated pedestal keeps the bearings cooler. At higher temperature a separated pedestal design is used, with fixed and floating bearings so the parts can grow, and expansion bellows in the duct.
A shaft cooler and a cooling disc carry heat away from the shaft, and an insulated pedestal keeps the bearings cooler. At higher temperature a separated pedestal design is used, with fixed and floating bearings so the parts can grow, and expansion bellows in the duct.
Sources: AMCA (Air Movement and Control Association), ISO (International Organization for Standardization).
Engineering & Standards
Before finalizing fan wheel diameter and motor rating, cross-check impeller geometry across our radial, radial-tip, and backward-inclined ID blower types, compare negative-suction versus positive-supply duty on our ID blower vs FD blower guide, verify thermal expansion density with the hot gas volume calculator, and confirm alloy limits in our flue-gas material selection chart.
For multi-unit plant bids and wider centrifugal fan engineering, review the AS Engineers centrifugal blower selection and sizing guide and centrifugal blower RFQ datasheet reference.
Standards Referenced: AMCA Standards 99 & 210 (Air Movement and Control Association); ISO 5801 & ISO 21940-11 Rotor Balance Requirements; Central Pollution Control Board (CPCB) Industrial Stack & APC Draft Guidelines.
Share the gas, temperature, airflow and pressure. Get a fan recommendation and a quote within one working day.