Induced draft blowers · ID, FD and high temperature · ISO 9001:2015 certified · Ahmedabad, IndiaInduced draft blowers · ID, FD and high temperature · ISO 9001:2015 certifiedGas up to 650 °C · built to your airflow and pressureMade in Ahmedabad · Quote within one working day

Types

Types of Induced Draft Blowers

Backward curved, radial blade and high temperature plug induced draft blowers: which one suits clean, dusty or very hot flue gas. From AS Engineers, Ahmedabad.

  • ISO 9001:2015 · TÜV certified
  • 25+ years · 3000+ customers
  • Engineered to your process

Types

Which induced draft blower for which gas

The impeller decides how an ID blower behaves. A backward curved impeller is efficient and does not overload the motor, so it suits clean or lightly dusty flue gas. A radial blade impeller is a sturdier shape for dusty, dirty or sticky gas and for high pressure. A high temperature plug blower is chosen when the gas is very hot.

We pick the type from your gas, temperature, dust load and pressure, not from a catalogue.

  • Backward curved: efficient, non-overloading power curve
  • Radial blade: for dusty or sticky flue gas
  • Plug blower: single or double inlet, for hot gas

What we supply

Induced draft blowers for every kind of flue gas

AS Engineers designs and builds induced draft blowers for furnaces, boilers and kilns, in backward curved, radial blade and high temperature plug designs. Pick the one you need, or tell us your duty and we will recommend it.

Backward curved ID blowers

Efficient centrifugal blowers with a non-overloading power curve. The usual choice for clean or lightly dusty flue gas, and they can also serve as forced draft blowers.

Best for Clean to lightly dusty flue gas

Get a quote

Radial blade ID blowers

A sturdier impeller shape for dusty, dirty or sticky flue gas and for high static pressure. Open or closed configurations.

Best for Dusty, dirty or sticky gas

Get a quote

High temperature plug blowers

Single or double inlet fans for hot air and gas up to 650 C, with the material, bearing and cooling arrangement chosen for the temperature.

Best for Furnaces, ovens, kilns and hot gas recirculation

Get a quote

High pressure blowers

High pressure radial blade blowers for duties where the furnace, heat recovery and duct add a lot of resistance.

Best for High static pressure

Get a quote

Industrial exhausters

Industrial exhauster blowers for furnace exhaust, fume and process air handling.

Best for Furnace exhaust and process air

Get a quote

Fans made to order

When the duty point is not a standard one, we engineer the impeller, casing and drive to your specification.

Best for Retrofit or a one-off duty

Get a quote

ID fan vs FD fan

Which fan does what?

A furnace normally has both. They do different jobs and are built differently.

Forced draft (FD) fanInduced draft (ID) fan
PositionBefore the furnaceAfter the furnace
HandlesClean combustion airHot, often dusty flue gas
Pressure effectRaises pressure in the furnaceLowers pressure in the furnace (draught)
Main concernAir volume to match the fuelTemperature, dust and corrosion
Typical impellerBackward curvedBackward curved or radial blade, by dust load
MaterialUsually mild steelChosen from the gas temperature and composition

Temperature and material

What a fan is made of at your gas temperature

AS Engineers builds fans for gas from ambient up to 650 °C. The hotter the gas, the more the material, bearing arrangement and cooling matter.

Gas temperatureTypical materialNotes
Up to 150 °CMild steelStandard construction
150 to 250 °CMild steel or SS 304Choice depends on the gas and how corrosive it is
250 to 350 °CMild steel, SS 304 or SS 321Separated pedestal design is used above about 300 °C
350 to 500 °CSS 321 or SS 310Shaft cooler and insulated pedestal
500 to 650 °CSS 310 or a high temperature alloyEvery duty is reviewed individually

These are typical choices. The final choice depends on the gas composition, how corrosive or abrasive it is, and whether the temperature is steady or cycles.

Range

The range our centrifugal fans cover

These are the stated ranges of the AS Engineers centrifugal fan and blower range. Your own duty point decides the actual fan.

ParameterRange
Airflow100 to 2,50,000 m³/hr (design up to 3,50,000 m³/hr)
Static pressure25 to 2,100 mmWC
Motor power0.5 to 500 HP
Impeller diameter250 to 2,200 mm
Fan speed300 to 4,500 RPM
Operating temperatureAmbient up to 650 °C
Performance testingIS 4894 (BIS)
Dynamic balancingISO 1940-1, Grade G6.3 / G2.5
Quality systemISO 9001:2015 certified

Fan parts

What is inside an induced draft blower

Each part has one job. A fan lasts when all of them are chosen for the same gas and the same temperature, and when the centrifugal blower rotation and discharge orientation match your duct layout.

1Impeller

The wheel that moves the gas. Backward curved blades give a non-overloading power curve and good efficiency. Radial blades suit dirty or sticky gas.

2Casing and inlet

The scroll casing guides the gas to the outlet. Single inlet (SWSI) or double inlet (DWDI) construction is chosen from the airflow.

3Shaft, bearings and seal

Fixed and floating bearings take the thermal growth. Stuffing box or mechanical seal keep hot gas inside the casing.

4Cooling arrangement

Shaft cooler, cooling disc and an insulated pedestal keep the bearing temperature down when the gas is hot.

5Material of construction

Mild steel, carbon steel, stainless steel grades or duplex, chosen from the gas temperature and how corrosive or abrasive it is.

6Drive

Belt-driven or direct-coupled, in the standard drive arrangements. A separated pedestal design is used at high temperature.

7Expansion bellows and dampers

Bellows take up duct expansion so hot ducting does not load the fan. Inlet vane or damper control the airflow.

8Controls

Starter or variable frequency drive, and vibration and temperature sensors for safe, stable running.

Before we quote

Six facts we need to select your fan

Do not worry if you do not have all of them. Send what you know, and our engineers will ask for the rest.

1Gas

Hot air, flue gas or process gas, with its composition if it is corrosive, wet or dusty.

2Temperature

Normal and peak gas temperature at the fan inlet.

3Airflow

Volume in m3/hr or Nm3/hr, and whether it is at actual or normal conditions.

4Pressure

Static pressure the fan must develop, or the duct and furnace resistance.

5Duty

Induced draft, forced draft or recirculation, number of fans, standby needs.

6Site

Power supply, space limits, a layout sketch, fuel and any CPCB or safety requirements.

FAQ

Technical questions

What gas temperature can your fans handle?

Our centrifugal fan range covers operating temperatures from ambient up to 650 °C. The material and construction change with temperature: mild steel at lower temperatures, then SS 304, SS 321 and SS 310 as the gas gets hotter. Duties above 500 °C are reviewed one by one.

What gas temperature can your fans handle?

Our centrifugal fan range covers operating temperatures from ambient up to 650 °C. The material and construction change with temperature: mild steel at lower temperatures, then SS 304, SS 321 and SS 310 as the gas gets hotter. Duties above 500 °C are reviewed one by one.

What airflow and pressure range do you cover?

Airflow from 100 to 2,50,000 m³/hr, with designs up to 3,50,000 m³/hr, and static pressure from 25 to 2,100 mmWC. The motor range is 0.5 to 500 HP and the impeller diameter 250 to 2,200 mm.

What airflow and pressure range do you cover?

Airflow from 100 to 2,50,000 m³/hr, with designs up to 3,50,000 m³/hr, and static pressure from 25 to 2,100 mmWC. The motor range is 0.5 to 500 HP and the impeller diameter 250 to 2,200 mm.

What is the difference between backward curved and radial blade impellers?

A backward curved impeller gives good efficiency and a power curve that does not overload the motor, so it is the usual choice for clean or lightly dusty gas. A radial blade impeller is a sturdier shape that suits dusty, dirty or sticky gas and high pressure duty.

What is the difference between backward curved and radial blade impellers?

A backward curved impeller gives good efficiency and a power curve that does not overload the motor, so it is the usual choice for clean or lightly dusty gas. A radial blade impeller is a sturdier shape that suits dusty, dirty or sticky gas and high pressure duty.

How do you cool a fan that handles hot gas?

A shaft cooler and a cooling disc carry heat away from the shaft, and an insulated pedestal keeps the bearings cooler. At higher temperature a separated pedestal design is used, with fixed and floating bearings so the parts can grow, and expansion bellows in the duct.

How do you cool a fan that handles hot gas?

A shaft cooler and a cooling disc carry heat away from the shaft, and an insulated pedestal keeps the bearings cooler. At higher temperature a separated pedestal design is used, with fixed and floating bearings so the parts can grow, and expansion bellows in the duct.

Need an ID blower for your furnace?

Send the gas, temperature, airflow and pressure. We reply with a recommendation within one working day.

Request your free quote

Step 1 of 2 · takes 30 seconds
What do you need?

Airflow, if you know it (m³/hr)

No spam · reply within one working day

Where should we send your proposal?

Prefer to talk? +91 99090 33851 · WhatsApp

Ready when you are

Induced draft blowers built for reliable plant exhaust.

Tell us your gas, temperature and airflow. We reply with a fan recommendation within one working day.

[ase_paddle_divider]
Chat with us
Secure form

Get your blower quote

Step 1 of 2 · takes 30 seconds
What do you need?

Airflow, if you know it (m³/hr)

No spam · reply within one working day

Where should we send your proposal?

Prefer to talk? +91 99090 33851 · WhatsApp

SSL-encrypted. Your details go only to our engineers – never shared or sold.